Symptom: BMC show CPU 0,1 PROCHOT alert when a PSU is removed or AC loss ,as shown in the fighre below. Cause: Since the PSU and CPU share the PMBUS circuit, when a PSU event is triggered, it will also simultaneously trigger a CPU event, which will ...
Broadcom P1400GDF30 “Link at lower Speed” Q&A Q: What's mean 'Linked at lower speed' in the Broadcom P1400GDF data sheet? A: Lower speed means lower than target (Max.) speed. It means the LED will turn amber if the link speed is lower than 400G.
Attachment is our assessment at NPI stage, we and intel decided NOT to support since HBM will request thicker baseboard and cause that existing CYP off shelf chassis can not be leveraged.
This issue is related to NVRAM due to custom bios setting saved in NVRAM. Please follow Intel server Firmware Update Utility use guide Page18 to add "UpdateNvram " parameter. User guide link: ...
For MiTACDSG Server products: 1. Please prepare SN of your server system or key component 2. Go to MiTACDSG portal as below, and enter the SN to check the end date of warranty MiTAC - Warranty Check
You could apply RMA from MiTAC ticket system by providing related SN, failure symptoms, event logs and after FAE judge the defective parts, then MiTAC Service team would issue RMA# to you for RMA return process. 1.Customer requests Technical Support ...
Yes, for created ticket, it's allowed customer to reply via your email system, and add member in mail COPY loop whoever OWN or NOT OWN ticket account. And after ticket replied, he/she could see the ticket thread in his/her email system. In case same ...