Question
What are the Dedicated LAN port and EMP Support Limitation of the D50DNP and D50TNP?
Answer
The TNP Block Diagram:
The BMC AST2500 on the TNP connects its NC-SI interface to Port 6 of a 7-port Micrel KSZ9897S switch. Port 7 of the switch connects to the EMP, while Port 3 connects to the front RJ45 port. Therefore, the BMC dedicated LAN and EMP can be used simultaneously.
Micrel KSZ9897S is 7-Port Gigabit Ethernet Switch with SGMII and RGMII/MII/RMII Interfaces.
The DNP Block Diagram:
The DNP Dedicated LAN uses the BCM54210S, which is not an Ethernet switch but a PHY that supports selectable interface modes. DNP uses the same BCM54210S to select between the Copper and SGMII paths. Therefore, these two paths cannot be used simultaneously.
Therefore, on DNP, even if no RJ45/LAN cable is connected to the EMP Module, simply installing the EMP Module in the system will cause the BMC to switch to the EMP/SGMII path, making the Dedicated RJ45 port unavailable.
Broadcom BCM54210 is Single Port RGMII SGMII Gigabit Ethernet Transceiver.