General
What power cable do I need to select to install an Nvidia H200 NVL in a MiTAC FT65T series system?
Question: What power cable do I need to select to install an Nvidia H200 NVL in a MiTAC FT65T series system? Answer: The MiTAC FT65T chassis can install up to one Nvidia H200 NVL GPU card. Customers need to order one MiTAC P/N 422B00700009 to connect ...
What power cable do I need to select to install an Nvidia H100 NVL in a MiTAC FT65T series system?
Question: What power cable do I need to select to install an Nvidia H100 NVL in a MiTAC FT65T series system? Answer: The MiTAC FT65T chassis can install up to two Nvidia H100 NVL GPU cards. Customers need to order MiTAC P/N 422T61300019 to connect ...
Why is nvidia-smi failing to detect Nvidia RTX 6000 Pro GPU card on Ubuntu Q&A
Why is nvidia-smi failing to detect Nvidia RTX 6000 Pro GPU card on Ubuntu Q&A Q: Why is nvidia-smi failing to detect Nvidia RTX 6000 Pro GPU card on Ubuntu? A: The Nvidia driver doesn’t support the Nvidia RTX 6000 Pro GPU card. You can resolve this ...
HOWTO SETUP RAID5 on Whitley Platforms
HOWTO SETUP RAID5 on Whitley Platforms
What is the SC513G6M2NRE(-2V) BMC default username and password?
Question: What is the SC513G6M2NRE(-2V) BMC default username and password? Answer: The SC513G6M2NRE(-2V) BMC default username and password of as below. Username: admin Password: 0penBmc123
What is the R2513G6HYPD(-2V) BMC default username and password?
Question: What is the R2513G6HYPD(-2V) BMC default username and password? Answer: The R2513G6HYPD(-2V) BMC default username and password of as below. Username: admin Password: 0penBmc123
The VROC key is bound to the motherboard serial number.
When applying for a VROC license, the motherboard serial number must be provided to Intel in order to bind the VROC license. If your VROC license is purchased through CTO, MiTAC will bind the VROC key directly to the current motherboard serial number ...
How to use inband redfish in windows on R2520G6?
This article is based on ticket #2231 where customer is confused and wandering how to setup inband redfish on windows 11 on Mitac R25220G6 system and seems to get an Ip address of 169.254.0.17. After contacting the Engineers from HQ they think that ...
Regarding S8040GM4NE-2T hardware fault LEDs
Regarding S8040GM4NE-2T hardware fault LEDs The customer reported that on the S8040GM4NE-2T, a pair of hardware fault LEDs is blinking Resolution: Update the BIOS and BMC to the latest versions, and clear the logs.
How to enable a 50/50 active-active PSU mode for both PSUs on M50CYP servers
The PSU default is cold redundancy enabled. This improves power efficiency as a higher loaded PSU is more energy efficient. The PSUs also have a rotation timer which causes the primary PSU to switch back and forth. Disabling cold redundancy will put ...
How to locate U.2 NVMe devices on GRAID SupremeRAID adapters?
Question: How to locate U.2 NVMe devices on GRAID SupremeRAID adapters? Answer: GRAID SupremeRAID adapters: SR-1000: NVIDIA T1000 (PCIe 3.0 x16) SR-1001: NVIDIA T400 (PCIe 3.0 x16) SR-1010: NVIDIA RTX A2000 (PCIe 4.0 x16) We can use GRAID graidctl ...
Which GPU power cable can I use on my B8261T85E8HR-2T-N-HE with H200?
Please use the following corresponding cable on the B8261-HE. Part Number MM Number Product Code Description 422B03800016 MKM00000217 FRU-CS-2770 AC/DC POWER CABLE;16 AWG,350 mm,1 TO 1; GPU PWR CABLE,TN85-B8261 (for H200 GPU card support) x10pcs
Why S7130 can's support CPU that it's over 270W(TDP)
Why S7130 can's support CPU that it's over 270W(TDP)
Why need to install 4 pin 12V power cable to S7130 J6 4 pin connector
Why need to install 4 pin 12V power cable to S7130 J6 4 pin connector
Does the B8261 series support a single-CPU configuration?
Answer: No, we do not guarantee single-CPU configurations. Please use two CPUs of the same model whenever possible.
What MRDIMM speed specifications are supported by the G4520G6U2BC-N?
The G4520G6U2BC-N supports Intel Xeon 6700/6500 series CPUs. For the Xeon 6700 P-core series CPUs, only MRDIMM 8000 speed is supported, depending on specific CPU SKUs. MRDIMM 8800 speed is supported by the Xeon 6900 series CPUs.
Does the G4520G6U2BC-N system support 8xH200 NVL GPUs?
The G4520G6U2BC-N has been validated with 8 × H200 GPUs, configured with NVLink in four groups of two GPUs each. Regarding GPU support, please refer to the GPU compatibility list on the official website. ...
R2520G6 supports two H200 GPUs with NVLink Q&A
R2520G6 supports two H200 GPUs with NVLink Q&A Q: Does the R2520G6 Configured with two H200 GPUs NVLink? A: No, R2520G6 cannot support NVLINK. R2520G6 support H200, that still side by side.
B8261T85E8HR-2T-N-HE supports two H200 GPUs with NVLink Q&A
B8261T85E8HR-2T-N-HE supports two H200 GPUs with NVLink Q&A Q: Does the B8261T85E8HR-2T-N-HE Configured with two H200 GPUs NVLink? A: No, B8261T85E8HR-2T-N-HE cannot support NVLINK. B8261T85E8HR-2T-N-HE thermal supports limitation, cannot install two ...
Why is the PCIe link speed on the NVIDIA RTX PRO 6000 Blackwell Max-Q, 4500 GPU card downgraded to Gen1, even though the connection supports Gen5?
Question Why is the PCIe link speed on the NVIDIA RTX PRO 6000 Blackwell Max-Q, 4500 GPU card downgraded to Gen1, even though the connection supports Gen5? Answer Because installing the latest driver has put the GPU in lower performance mode. The GPU ...
UEFI BIOS Recovery for B7129
UEFI BIOS Recovery for B7129
B8050F65TV8E2H-N_B8050F65TV8E2H-2T-N Cooling Kit Requirements with H200 RTX PRO 6000 BSE GPUs Q&A
B8050F65TV8E2H-N / B8050F65TV8E2H-2T-N Cooling Kit Requirements with H200 / RTX PRO 6000 BSE GPUs Q&A Q: Does the B8050F65TV8E2H-N/ B8050F65TV8E2H-2T-N server require an additional or optional Cooling Kit when configured with the H200 or RTX PRO 6000 ...
(R520G6) If VROC key becomes inactivate
Q: If VROC key becomes inactivate A: If you were previously using a VROC key, but it became inactive after the DC-SCM replacement. The VROC license is bound to the motherboard, if you only replace the DC-SCM, you should be able to reactivate the VROC ...
How to edit BMC FRU
To edit the BMC FRU in the event of corruption, errors or changes you can use ipmitool which is available for all LNX OS and for Windows using ipmitool.exe . In order to edit the FRU you need to know the field type, of which you can follow the chart ...
Regarding the 8-pin power connector on the B8056T70AE26HR-2T-HE-TU Power Distribution Board,
Regarding the 8-pin power connector on the B8056T70AE26HR-2T-HE-TU Power Distribution Board. According to Taiwan team's original design, the 8-pin connector is reserved for GPU support.
GRAID-SupremeRAID-Linux and Windows User-Guide
GRAID-SupremeRAID-Linux and Windows User-Guide
All stock BMC password related
This article is based off the Forgot BMC Password article published by Ruben Tercero on June 30 2025 in the case of forgetting your bmc passwords you can follow this to reset your bmc password we are using linux ubuntu budgie live for resetting ...
how to check the ROT firmware using a raw command in Linux?
If you need to check the ROT firmware version from the OS, you can try using the raw command below. Command: raw 0x6 0x52 0x9 0x70 0x2 0x0 Sample result: ROT: 24 corresponds to version v02.04.
TSM+PXE settings (Windows and Linux)
TSM+PXE settings (Windows and Linux)
Why can a single ADVSYSMGMTKEY activate multiple servers in the Intel DSG product
Question Why can a single ADVSYSMGMTKEY activate multiple servers in the Intel DSG product Answer The ADVSYSMGMTKEY is sold by Intel. A single license key file can activate multiple servers, but the maximum number of activations is limited to the ...
Regarding the B8056T70AE26HR-2T-HE-TU HDD backplane when U.2 drives are installed in the 2.5 NVMe bays 8–15 (8 drives)
Regarding the B8056T70AE26HR-2T-HE-TU HDD backplane when U.2 drives are installed in the 2.5 NVMe bays 8–15 (8 drives). The system is not fully compatible with PCIe 5.0 devices. In certain situations, using PCIe 5.0 devices on the HDD backplane of ...
How to install PXE server in CentOS 7.3
How to install PXE server in CentOS 7.3
R2520/1520 Fan Speed Control
Please use PWMTach Tool for fan speed control
how to install and populate mitac S8016AGM2NR motherboard memory dimms correctly
this guide is based on ticket 2108 where user has installed wrongly on our motherboard Tyan S8016AGM2NR which results in boot up bios posting error following the official guide below https://download2.mitaccomputing.com/pub/doc/S8016_UG_v1.0b.pdf The ...
How can I determine whether the BMC on a Tyan server is corrupted?
To check whether the BMC on our Tyan product line is functioning or corrupted, you can look at the BMC heartbeat LED on the motherboard or on the front panel board. If the LED is blinking, the BMC is operating normally. If the LED is solid green or ...
How to download The S5565 Bios that support Alder Lake-S DDR4/Raptor Lake-S DDR4/Bartlett Lake-S DDR4
https://www.mitaccomputing.com/en/downloads/Motherboards/S5565_S5565AG2NR#dw BIOS5565010107.ROM - Date : 08/05/2025 - Checksum32 : 0xE66A5905(CRC32) - Banner : TYAN S5565AG2NR V1.07 - Codebase : 5.32_1AZJN_RC0C.00.FB.20(6073.02)_047 - CPU : Alder ...
Intel VROC for Windows (Intel DSG systems only.)
Unlike Linux, Intel VROC (VMD) for Windows requires specific drivers. Specifically, said drivers need to be installed during OS installation. Additionally, the driver package used differs depending on which PCH chipset the system uses. Links to said ...
R2520 / R1520 PCIe Cards missing or misreporting Root Port (Network etc)
Please check the VMD is disabled unless using the backplane expander and VROC for those PCIe Slots. VMD will interfere with regular PCIe card function.
Link to Downlaod the AMD_ Video AM5 EPYC Driver For S8016
https://www.mitaccomputing.com/en/downloads/Motherboards/S8016_S8016AGM2NR#dw
The recommended system memory (RAM) configuration for MI325X/MI350X (G8825Z5)
According to the AMD Instinct Customer Acceptance Guide, the minimum system memory for MI325X — in environments without virtual machines or with only a single VM — is 2.5 TB / in environments with virtual machines is 6.0 TB. The minimum system memory ...
Next page