General
What is the difference between B8261T85E8HR-2T-N-HE and B8261T85E8HR-2T N?
Question: What is the difference between B8261T85E8HR-2T-N-HE and B8261T85E8HR-2T-N? Answer: Due to upgrade of two easy to swap 8038 rear Fans in the B8261T85E8HR-2T-N HE, the system can support GPU modules with higher power consumption (600W). This ...
Why D50DNP have no M.2 sensor show up when installed MICRON 5400
Fail symptom :BMC has no M.2 sensor show up , but M.2 device MICRON5400 (MTFDDAV480TGA) can be found in BMC storage Information menu BMC storage information: No M.2 sensor in sensor menu Root cause: Microm 5400 M.2 is SATA device which do not support ...
How to check Mellanox Network adapter's firmware in Linux?
Question: How to check Mellanox Network adapter's firmware in Linux? Answer: The firmware for the corresponding network card can be downloaded from the official website. Please refer to the following download instructions. e.g., Mellanox ...
R1520G6 BMC Web UI login Password FAQ
R1520G6 BMC Web UI login Password FAQ Q1. Refer to the AST2600 user's guide. The OpenBMC password cannot be used to log in. I tried "OpenBmc123" and "OpenBmc123.", but both were invalid. Ans: The first character is a digit, not a letter. Please try ...
How to use IPMI commands to get/control system status on R1520G6/R2520G6
Question How to use IPMI commands to get/control system status on R1520G6/R2520G6 Answer This document explains how to use IPMI commands via two methods to get/control system status. IPMI (Local): Executed locally on R1520G6/R2520G6 Linux O/S. IPMI ...
How to obtain warranty service?
Question How to obtain warranty service? Answer To obtain warranty service for the product, you may contact your original place of purchase in accordance with its instructions, or contact MiTAC if you purchased from MiTAC directly. Go to MiTAC online ...
How to use ipmi command to set next boot as PXE boot
If customer needs to use ipmi command to set system next boot as PXE boot. Then customer can use below command to let their system boot to PXE mode at next power-on. ipmi command: #ipmitool chassis bootdev pxe (for Legacy mode) #ipmitool chassis ...
How to disable R2520 redfish
Please boot into BIOS and change BIOS setting Advanced > Redfish Host Interface Settings -> Redfish from “Enabled” to “Disabled”
How to install IO Rail for OCP Card on B8056?
Question How to install IO Rail for OCP Card on B8056? Answer You may refer to section 2.1.9- installing IO Rail for OCP Card, page 54 of the user guide. Follow these instructions to install the IO rail for OCP Card. Here is a sample showing how to ...
S8016AGM2NR MB Front Panel Header definition
S8016AGM2NR MB Front Panel Header definition 1. Check the Front Panel Header on S8016AGM2NR User Guide V1.0c. MiTAC S8016 S8016AGM2NR Documentations 2. About the S8016AGM2NR Front Panel Header: Pin 1-3 is HDD LED (Pin1 is LED+ /Pin3 is LED-) Pin 2-4 ...
Step-by-Step Guide: Enabling TPM 2.0 and Installing Windows 11 Pro on Mitac system
Step-by-Step Guide: Enabling TPM 2.0 and Installing Windows 11 Pro on system In this guide we will show you how to install win 11 pro on Mitac system with tpm2.0 installed on the mb(motherboard) the board used is the Mitac S5642AGM3NRE-2T with ...
Ipmi command "ipmitool sel list " doesn't show sel log on D50DNP system.
Fail symptom : No message print after perform "ipmi sel list " , only show "sel has no entries" Root cuase : OpenBMC does not have the static SDR design like legacy BMC, so when adding a SEL entry via a raw command, the BMC will attempt to map it ...
DDR5 Memory Population Rule Restriction on R1520G6/R2520G6.
R1520G6/R2520G6 supports DDR5 RDIMMs with the following feature: • 8 channels DDR5, Up to 6400 MT/s (1DPC), 5200MT/s (2DPC) This means If plug 6400MHz RDIMM on R1520G6/R2520G6, the memory speed can work on 5200 MT/s in 2DPC. If plug lower than ...
What's the suggest coolant type for DNP liquid-cooled system
As Intel suggestion , the coolant type is “Recochem OAT PG25” MiTAC Server D50DNP Family Technical Product Specification Page 99 ...
HOWTO INSTALL WINDOWS 2022/2025 DRIVER ON HG68-B8016/GX40-B8016/S8016AGM2NR
Step 1: To install Windows 2025 O/S, HG68-B8016/GX40-B8016/S8016AGM2NR should be updated to the following BIOS version A. BIOS v2.07 (0x30) for HG68-B8016 (Link: MiTAC Server - Downloads ) B. BIOS v2.05 (0x31) for GX40-B8016 (Link: MiTAC Server - ...
Issue with running FUP update with 24 OR 32 pcs RDIMM on R1520G6 and R2520G6
This FUP FW package can update normally when using 2, 8, or 16 pcs RDIMM modules configuration. The update will fail with “BmcLibInitialize returned failed” error messages during loading ipmi.efi driver when the memory configuration is set to 24 or ...
How to find Product Manuals
How to find Product Manuals
How to find product specifications
How to find product specifications
Power cable for NVIDIA H100 GPU on FT65T-B8050 and B5652
The power cable for NVIDIA H100 GPU, MiTAC P/N:422T61300019. * Pine Definition Power cable for NVIDIA H100 GPU
Intel VROC Quick Configuration Guide
Intel VROC Quick Configuration Guide
How to perform BIOS update for Intel® Server Boards.
How to perform BIOS update for Intel® Server Boards
How to Find Product Change Notifications and Product Discontinuance Notifications
Product Change Notifications on MiTAC's Resource and Documentation Center allows users to search, view and download Product Change Notifications, Product Discontinuance Notifications for Intel products.
Intel_SGX_SW_Installation_Guide_for_Linux
Intel_SGX_SW_Installation_Guide_for_Linux
Does DNP support Intel TME ?
DNP support Intel TME and need to enable BIOS setting as below picture. TME (Total Memory Encryption) function default is disable. About Intel TME feature , please refer Intel white paper. ...
HOWTO CHECK TN85-B8261 AMBIENT TEMPERATURE
To check ambient temperature of TN85-B8261, you can check the SYS_AIR_INLET sensor by issuing 'ipmitool sdr elist | grep -i sys_air_inlet' or by checking BMC Web GUI Sensor Reading 1. Reading SYS_AIR_INLET sensor via ipmitool sdr elist 2. Reading ...
AMD BIOS CBS Setting Basics
AMD BIOS CBS Setting Basics
How to use IPMITOOL to modify BMC FRU file
How to use IPMITOOL to modify BMC FRU file
R1520G6 R2520G6 System Fan Keeps Running in the ACPI-S5 State
R1520G6 / R2520G6 System Fan Keeps Running in the ACPI-S5 State (DC-OFF).
Mitac EGS Platform Get BSOD Issue while installing WS2019 OS
Mitac EGS Platform Get BSOD Issue while installing WS2019 OS
All PSUs MUST have AC Cord Plug on G4520G6
The G4520G6 power supply system outputs 9,600 watts with a 3+1 redundancy configuration. All PSUs MUST have AC cord plug to ensure proper functionality. If a power supply modules is installed but not connected to an AC power source, it will trigger a ...
How to check and enable /disable D50TNP power supply code redundancy
Please use Syscfg utility or IPMI tool raw command to check and enable/disable PSU CR feature. https://www.intel.com/content/www/us/en/support/articles/000025905/server-products/server-boards.html IPMI command : ipmitool raw 0x30 0x2e 0x01 Return ...
Need to setup “Performance” mode in Bios setup menu when using H100/L40/L40s GPU card on M50FCP2UR208 and M50FCP2UR216.
If the end user installs H100/L40/L40s GPU card on M50FCP2UR208 and M50FCP2UR216, the end user needs to install FCPGPGPU kit and manually switch fan profile to “Performance” mode in BIOS setup utility. BIOS setup utility: Advanced-->System Acoustic ...
HOWTO USE FRUEDIT ON UEFI-Built-in-Shell
HOWTO USE FRUEDIT ON UEFI-Built-in-Shell
Why TURIN SKU of B8056-TU Memory Not Run in 6400MHz
In the AMD document, the table below lists the memory frequency limitation in AMD SP5 TURIN 2DC design.
DDR5 MRDIMM (Multiplexed Rank DIMM ) support Intel Xeon 6500P/6700P-series processors.
The Ranks Per DIMM/Data Width are 2Rx8 and 2Rx4, the capacity up to 32Gb and 64GB under 1DPC. If Ranks Per DIMM and Data Width is 2Rx8, the MRDIMM Capacity up to 32GB If Ranks Per DIMM and Data Width is 2Rx4, the MRDIMM Capacity up to 64GB. Please ...
ovirt4.4 Installation and Deployment
ovirt4.4 Installation and Deployment
HOWTO SEARCH VMWARE CERTIFIED PRODUCTS FROM MITAC WEBSITE
Please click the attached file to check on how-to search Mitac website for vmware certified products
MiTAC OTS Front Panel Conversion Cable
MiTAC OTS Front Panel Conversion Cable In the S8040, S7130, S7136… motherboards, the onboard connector FPIO_2 (or FPIO_1, as defined by the motherboard) is the front panel header. It is a 1.0mm 2x12 pin header. In the chassis, the front panel header ...
Intel Vroc key raid 10 maximum drives supportted
The Intel vroc key is an enterprise RAID solution that can support different raid levels from Raid 0,1,5to 10 depends on the vroc version you chosen however if you are setting up raid 10 the limitation is limited to 4 drives only even if you have ...
How to choose product “Family Name” while creating ticket?
Provide guideline to choose right family name in quicker way while creating a support ticket. (as enclosed attachment)
Next page