General
Link to Downlaod the AMD_ Video AM5 EPYC Driver For S8016
https://www.mitaccomputing.com/en/downloads/Motherboards/S8016_S8016AGM2NR#dw
The recommended system memory (RAM) configuration for MI325X/MI350X (G8825Z5)
According to the AMD Instinct Customer Acceptance Guide, the minimum system memory for MI325X — in environments without virtual machines or with only a single VM — is 2.5 TB / in environments with virtual machines is 6.0 TB. The minimum system memory ...
How to enable the software VROC key on SC513G6
Attachment
Why does the R2520G6U2XD PSU draw less input current than the output current it provides?
Question: Why does the R2520G6U2XD PSU draw less input current than the output current it provides? Is it reasonable? Example: PSU 1 Input current: 0.58 Amps, PSU 1 output current: 7.14 Amps. The PSU input current is less than output current. Answer: ...
CPU Compatability B8261T85E24HR-2T /Conditional Support.
When a customer have a question about supporting the specific CPU and will see the following Conditional support . The conditional support is temperature related. the ambient temperature requirement for that CPU foe example on this CPU the limitation ...
Regarding the B8261T85E8HR-2T-N with one CPU installed, the server will not power on after the motherboard was replaced.
Regarding the B8261T85E8HR-2T-N with one CPU installed, the server will not power on after the motherboard was replaced. Below is the photo that shows the CPU is installed in socket 1 instead of socket 0. Resolution: The CPU needs to be installed in ...
How to easy see the difference between HE and non-HE SKUs on the B8056/ Output Watts
Support GPU Card for B7129
Support GPU Card for B7129
How to edit FRU information for the M50CYP MDSG system?
For the M50CYP MDSG system, customers can edit or rewrite the FRU information if it has been wiped out accidentally, using the FRU editing tool included in the FUP or SFUP file downloaded from our website . updM50FruSdr_CYP.nsh If the system shows ...
How to setup windows 11 using local account bypassing Microsoft account requirement during initial setup 2025
How to setup windows 11 using local account bypassing Microsoft account requirement during initial setup 2025 As of late 2025 Microsoft Windows 11 most editions require a Microsoft account and an internet connection to complete the initial setup ...
Regarding the BIOS/Redfish behavior of the S8016 motherboard
Regarding the BIOS/Redfish behavior of the S8016 motherboard. After updating the BIOS from version 3.06 to 3.07, the issue has been resolved. Please see the information below. When the PK is deleted through Redfish, the BIOS System Mode changes from ...
G8825Z5 not powering on
Please insure ALL 6 PSU are plugged in and have green LED's.
How to setup VROC RAID volume on G4520G6
How to setup VROC RAID volume on G4520G6
How to identify whether B8056 can use Gen5 U.2 NVME SSD.
Question: How to identify whether B8056 can use Gen5 U.2 NVME SSD. Answer: User wishes to use GEN5 U.2 NVME SSD must use B8056T70AE26HR-2T-2HE-TU product model as its HDD backplane support GEN5 U.2 NVME SSD. This document explains how to identify ...
Regarding the Zoho user agent that shows a red dot
Regarding the Zoho user agent that shows a red dot. Resolution: 1. Refresh the browser because Zoho might be idle 2. Clear the browser cache or use a different browser 3. Add the Zoho URL to the Performance settings (Always keep these sites active)
How to locate the Broadcom NIC card
As attachment
HOWTO MODIFY BIOS PARAMETER VIA CURL REMOTELY ON S8056 MOTHERBOARD
PREREQUISITE: Need to install the following packages on Remote Client (Ubuntu 20.04) apt install curl apt install python2 apt install jq Before modifying any BIOS parameter, you must first check the BIOS Attribute Registry for the name of parameters ...
How to see the PCIE enumeration B8251T83E8HR-2T-N-EDA GPU
B8251T83E8HR-2T-N-EDA GPU enumeration..
How to set up B8251 Raid support configuration using the following BP M1317T83-BP12E-8
To set up RAID on the B8251 server with backplane model BP M1317T83-BP12E-8, please follow the instructions below.
How to Enable the serial Over Lan ( SOL) Console on G4520G6 This article include OS settings example Ubuntu 24.04.3 Linux OS
How to enable the Serial Over Lan(SOL) Console on G4520G6 How to Enable Serial Over LAN (SOL) Console on G4520G6U2BC This guide outlines the steps to enable the Serial Over LAN (SOL) console on the G4520G6U2BC server. The configuration involves two ...
How can I identify the chip manufacturer of my R2520G6U2XD re-timer card?
Question: How can I identify the chip manufacturer of my R2520G6U2XD re-timer card? Answer: There’re two manufacturers of R2520G6U2XD re-timer card. You can identify these two cards by the header’s location as below. 1. Manufacturer Montage: Headers ...
Broadcom Driver install_Niccli Utility_Frimware update SOP
As attachment
update linux kernel 5.19
update linux kernel 5.19
How to check CPU core under OS.
There are two command to check CPU core under OS. 1.Command: lscpu 2.Command: nproc
What is the difference between B8261T85E8HR-2T-N-HE and B8261T85E8HR-2T N?
Question: What is the difference between B8261T85E8HR-2T-N-HE and B8261T85E8HR-2T-N? Answer: Due to upgrade of two easy to swap 8038 rear Fans in the B8261T85E8HR-2T-N HE, the system can support GPU modules with higher power consumption (600W). This ...
How to Reseat the BMC/IPMI Module When It's Slow or Unresponsive on The G4520
Try sending the IPMI raw command( this cmd will reseat the BMC) If the IPMI command executes successfully but the issue persists, proceed to flash the BMC using the Linux script included in the BMC package. If the BMC is completely unresponsive and ...
How to test the G8825Z5 computer node only
GPU Module Disable Instructions for Node Testing When testing the computer node only, please set jumper J2 to disable the GPU module. For detailed instructions, refer to page 86 of the service manual.
How-To Modify BMC Password and Login to BIOS Redfish
How-To Modify BMC Password and Login to BIOS Redfish
How to update BMC Firmware on G8825Z5 with Ubuntu 22.04.02
How to update BMC Firmware on G8825Z5 with Ubuntu 22.04.02 Hardware Environment: MiTAC G8825Z5 GPU server BIOS: v1.00 BMC: v1.00 CPU: AMD EPYC 9575F x2 RAM: DDR5-5600 64GB x 24 OS: Ubuntu 22.04.2 LTS Server Prerequisites For Ubuntu 22.04 LTS: For a ...
HOW TO CHECK THE CPLD VERSION ON THE B8261 BMC WEBGUI
IF CUSTOMER ASK OR NEED TO FIND THE CPL VERSION . PLEASE FIND IT IN THE DASHBOARD ( SEE BELOW)
WHEN END USER ASK WHERE TO purchase the front panel cable (Part #422B00700007) for a new-generation motherboard
When an end user asks where to purchase the front panel cable for the new-generation motherboard (Part #422B00700007), please refer them to the eBay link provided below. https://www.ebay.com/itm/197740999859
Network Link User Manual on Web BMC
Network Link User Manual on Web BMC 1. Function Description: This function is used to configure the Link Speed and Duplex Mode of the server’s network interfaces With Auto Negotiation, the device automatically selects the optimal mode. If disabled, ...
How to check the CPLD FW & PCIe Switch FW on G4520G6
How to check the CPLD FW & PCIe Switch FW on G4520G6 Test Configuration Product Name: G4520G6 CPU: Intel(R) Xeon(R) 6787P *2 DIMM: Samsung 96G 5600MHz *2 HDD: Micron MTFDKCC7T6TGP 7680G *1 OS image: ubuntu-24.04.2-desktop-amd64.iso BIOS:v1.01 ...
Why D50DNP have no M.2 sensor show up when installed MICRON 5400
Fail symptom :BMC has no M.2 sensor show up , but M.2 device MICRON5400 (MTFDDAV480TGA) can be found in BMC storage Information menu BMC storage information: No M.2 sensor in sensor menu Root cause: Microm 5400 M.2 is SATA device which do not support ...
Why D50DNP BMC report PCIe Correctable Link Speed Changed?
From BMC warning information , the device is related to M.2 device As DNP TPS ,DNP support PCIe x4 Gen3 m.2 device , BMC would report Link speed change if installed Gen4 M.2 device. TPS Section 8.1
How to check Mellanox Network adapter's firmware in Linux?
Question: How to check Mellanox Network adapter's firmware in Linux? Answer: The firmware for the corresponding network card can be downloaded from the official website. Please refer to the following download instructions. e.g., Mellanox ...
HOWTO CHECK PRODUCTION DATE VIA SERIAL NUMBER
Barebone S/N Format: TC#PPWWP@@@@ Digit 1, 2 TC Vendor Code: TC means MSL TM means MIS TF means TUSA TH means HOU TY means OSE Digit 3 # Production Year – “3” means 2003 K means 2020 L means 2021 M means 2022 N means 2023 O means 2024 P means 2025 Q ...
R1520G6 BMC Web UI login Password FAQ
R1520G6 BMC Web UI login Password FAQ Q1. Refer to the AST2600 user's guide. The OpenBMC password cannot be used to log in. I tried "OpenBmc123" and "OpenBmc123.", but both were invalid. Ans: The first character is a digit, not a letter. Please try ...
How to use IPMI commands to get/control system status on R1520G6/R2520G6
Question How to use IPMI commands to get/control system status on R1520G6/R2520G6 Answer This document explains how to use IPMI commands via two methods to get/control system status. IPMI (Local): Executed locally on R1520G6/R2520G6 Linux O/S. IPMI ...
How to check Mellanox Network adapter's firmware in Windows and Linux?
Question: How to check Mellanox Network adapter's firmware in Windows and Linux? 1. Download mlxup - Update and Quert Utility from Nvidia. https://network.nvidia.com/support/firmware/mlxup-mft/ 2. Select mlxup by your operating system and download ...