General
How to run the “AMD GPU Stress test” on Ubuntu24.04
How to run the “AMD GPU Stress test” on Ubuntu24.04 Test Configuration Product Name: B8261 / 8050 /8030 CPU: AMD EPYC 9174F *2 / AMD EPYC 9534 / AMD EPYC 7713P DIMM: DDR5 6400 32GB*12 / DDR5 4800 32GB*8 / DDR4 3200 32GB*8 Graphics: AMD R9700 AI Pro*2 ...
How to Find Product Change Notifications and Product Discontinuance Notifications
Product Change Notifications on MiTAC's Resource and Documentation Center allows users to search, view and download Product Change Notifications, Product Discontinuance Notifications for Intel products.
Intel_SGX_SW_Installation_Guide_for_Linux
Intel_SGX_SW_Installation_Guide_for_Linux
Does DNP support Intel TME ?
DNP support Intel TME and need to enable BIOS setting as below picture. TME (Total Memory Encryption) function default is disable. About Intel TME feature , please refer Intel white paper. ...
HOWTO CHECK R2520G6/R1520G6 CS SAMPLE VIA SERIAL NUMBER
E7142 2U CS sample build date 09/02’24, 09/05’24, 09/06’24 fall on week 36, while 10/09’24 fall on week 41 (red box). E7142 1U CS sample build date 09/25’24 fall on week 39, while 10/08’24 fall on week 41 (red box). Every S/N for E7142 both 1U and 2U ...
HOWTO CHECK TN85-B8261 AMBIENT TEMPERATURE
To check ambient temperature of TN85-B8261, you can check the SYS_AIR_INLET sensor by issuing 'ipmitool sdr elist | grep -i sys_air_inlet' or by checking BMC Web GUI Sensor Reading 1. Reading SYS_AIR_INLET sensor via ipmitool sdr elist 2. Reading ...
How to verify DNP DTS minus reading is correct or wrong?
DNP offer 2 sensor reading as below l Die CPU: The temperature sensor reading of CPU Die l DTS CPU: The margin between Die CPU and SPEC. For example , CPU model is 6438N ,the DTS MAX is 96 DTS CPU = Die CPU - DTX max -52.39=43.56 - 96
AMD BIOS CBS Setting Basics
AMD BIOS CBS Setting Basics
IPMI command for clear CYP SW key.
Please perform below IPMI command in case you need to clear ASM key on CYP board. Command: ipmitool raw 0x3e 0x78 0x03
Ipmi command for clear FCP ASM /VROC software key.
Please run below command in case you need to clear the SW key on FCP board. Remove ASM Key: ipmitool raw 0x3e 0x78 0x3 0x1 Remove VROC Standard Key: ipmitool raw 0x3e 0x78 0x3 0x2 Remove VROC Premium Key: ipmitool raw 0x3e 0x78 0x3 0x3
B8261 product P5V error Document
B8261 product P5V error MB: B8261T85E8HR-2T-N BIOS: V3.00 BMC: 4.00 Issue: The P5V error is displayed in both the Web BMC and the BIOS. Root cause: BMC Version 2.01, Modify the SKUID and BMC MAC address to be placed on IO board instead of MB. The BMC ...
Broadcom Compatibility Guide Links for ESXi, HBA Controllers, and Intel NIC Firmware
Please refer to the Broadcom compatibility guide links below for ESXi, HBA Controllers, and Intel NIC Firmware https://compatibilityguide.broadcom.com/search?program=io&persona=live&column=brandName&order=asc ...
Broadcom Compatibility Guide Links for ESXi, HBA Controllers, and Intel NIC Firmware
Please refer to the Broadcom compatibility guide links below for ESXi, HBA Controllers, and Intel NIC Firmware https://compatibilityguide.broadcom.com/search?program=io&persona=live&column=brandName&order=asc ...
Forgot BMC Password
When come across of a customer forgot the BMC password follow this two quick solution 1) If customer have accessible Linux OS they can send the following ipmitool raw cmd as seen below . This will reset the BMC password as default 2) second option ...
How to check which power supply is not receiving power from the debug log of the Intel M50CYP2UR208
Check under General BMC Sensor Readings, check for the entry RD:0000 SN:PS1 Input Power to identify power issues. RD:0000 is currently reading 0 watts. Below is an example READING - S#:54 RD:0000 SN:PS1 Input Power
How to resolve the B8056T70AE26HR-2T and AMD 9334 that cannot pxe boot with onboard NIC
Resolution: The system needs to be updated to the new BIOS. Please visit our website to download the new BIOS. https://www.mitaccomputing.com/en/downloads/Barebones/TS70AB8056_B8056T70AE26HR-2T#dw Description: [Genoa] - Fixed AFU flash BIOS fail when ...
How to use IPMITOOL to modify BMC FRU file
How to use IPMITOOL to modify BMC FRU Ipmitool: v1.8.18 Command: ipmotool [-H hotst_IP –U username –P password] fru edit <fru id> field <section> <index> <string> Sample: ipmotool [-H hotst_IP –U username –P password] fru edit 0 field p 0 MiTAC <fru ...
How to check RoT version on R2520G6
How to check RoT version on R2520G6.
How to check CPLD firmware version on G4520G6
How to check CPLD version on G4520G6
How to check CPLD firmware version on R2520G6.
How to check CPLD firmware version on R2520G6.
How to locate HDD in B8056 by ipmitool raw command
For SKU B8056T70AE26HR & B8056T70V8E6HR
S8056-TU Series Memory Frequency Support Specification
The reason why S8056-TU series with AMD SP5 Turin CPU Memory Frequency don’t up to 6400Mhz
R1520G6 R2520G6 System Fan Keeps Running in the ACPI-S5 State
R1520G6 / R2520G6 System Fan Keeps Running in the ACPI-S5 State (DC-OFF).
Mitac EGS Platform Get BSOD Issue while installing WS2019 OS
Mitac EGS Platform Get BSOD Issue while installing WS2019 OS
M50FCP System Fan-4 Keep Running in the ACPI-S5 State
M50FCP System Fan Keeps Running in the ACPI-S5 State (DC-OFF) In the M50FCP server system configured with dual processors, dual PSUs, and an OCP Ethernet card, it is expected behavior for System Fan-4 to keep running even when the system is in the ...
All PSUs MUST have AC Cord Plug on G4520G6
The G4520G6 power supply system outputs 9,600 watts with a 3+1 redundancy configuration. All PSUs MUST have AC cord plug to ensure proper functionality. If a power supply modules is installed but not connected to an AC power source, it will trigger a ...
How to generate Google application password for Gmail
It's a SOP how to generate Google application password for Gmail
How to send B5642 BMC alert mail to Gmail SMTP server SOP
It's SOP how to send B5642 BMC alert mail to Google Gmail SMTP server
How to send S7130 BMC alert mail to Microsoft365 SMTP server SOP
It's a SOP how to send S7130 BMC alert mail to Microsoft365 SMTP server
How to check and enable /disable D50TNP power supply code redundancy
Please use Syscfg utility or IPMI tool raw command to check and enable/disable PSU CR feature. https://www.intel.com/content/www/us/en/support/articles/000025905/server-products/server-boards.html IPMI command : ipmitool raw 0x30 0x2e 0x01 Return ...
Need to setup “Performance” mode in Bios setup menu when using H100/L40/L40s GPU card on M50FCP2UR208 and M50FCP2UR216.
If the end user installs H100/L40/L40s GPU card on M50FCP2UR208 and M50FCP2UR216, the end user needs to install FCPGPGPU kit and manually switch fan profile to “Performance” mode in BIOS setup utility. BIOS setup utility: Advanced-->System Acoustic ...
HOWTO USE FRUEDIT ON UEFI-Built-in-Shell
HOWTO USE FRUEDIT ON UEFI-Built-in-Shell
Why TURIN SKU of B8056-TU Memory Not Run in 6400MHz
In the AMD document, the table below lists the memory frequency limitation in AMD SP5 TURIN 2DC design.
How to Enable the Software VROC in BIOS of R1520G6 R2520G6
The R1520G62, R2520G6 server support Intel Software VROC 9.0. The software VROC has two kinds license, one is Premium and the other one is Standard. The Premium software VROC license key supports RAID 0/1/5/10, the Standard software VROC license key ...
DDR5 MRDIMM (Multiplexed Rank DIMM ) support Intel Xeon 6500P/6700P-series processors.
The Ranks Per DIMM/Data Width are 2Rx8 and 2Rx4, the capacity up to 32Gb and 64GB under 1DPC. If Ranks Per DIMM and Data Width is 2Rx8, the MRDIMM Capacity up to 32GB If Ranks Per DIMM and Data Width is 2Rx4, the MRDIMM Capacity up to 64GB. Please ...
NV H200 GPU Power Cable for B8261T85E8HR-2T-N
NV H200 GPU Power Cable for B8261T85E8HR-2T-N Below is NV H200 GPU Power Cable for B8261T85E8HR-2T-N, MiTAC PN: 422B03800013. T1050H7A12502-2x6P+4P to 2x4P-GPU Power cable for H200-350mm.
ovirt4.4 Installation and Deployment
ovirt4.4 Installation and Deployment
HOWTO SEARCH VMWARE CERTIFIED PRODUCTS FROM MITAC WEBSITE
Please click the attached file to check on how-to search Mitac website for vmware certified products
Why TNP / DNP all nodes BMC port assigned IP when plug in network cable in 1 node only
Symptom: Installed networking cable in 1 node only ,but others nodes BMC assigned IP as well. Solution : Please check system rear side if installed EMP module . As below diagram , EMP module H/W design serial connect all nodes BMC port , so all nodes ...
MiTAC OTS Front Panel Conversion Cable
MiTAC OTS Front Panel Conversion Cable In the S8040, S7130, S7136… motherboards, the onboard connector FPIO_2 (or FPIO_1, as defined by the motherboard) is the front panel header. It is a 1.0mm 2x12 pin header. In the chassis, the front panel header ...